Home > Kohler Uninterruptible Power > Is it time to consider Lithium-ion batteries?

Is it time to consider Lithium-ion batteries?

Kohler Uninterruptible Power News and PR from Kohler Uninterruptible Power - Published 30 August 2017 Why hasn’t the industry adopted lithium-ion solutions with greater enthusiasm, and is this likely to change? We can answer these by looking at factors relating to both lead-acid and lithium-ion bat.
Lead-acid issues

Lead-acid batteries have long been the most widely accepted option, popular for their low cost and reliability. Their reputation was enhanced by the appearance of valve regulated lead-acid (VRLA) types. These sealed units are regarded as safer and more environmentally-friendly than the open, vented versions. However, these batteries are not ‘fit and forget’ devices; their voltage, internal resistance and operating temperature must be regularly monitored, to ensure they are correctly charged and in optimal condition. Several factors can reduce their working life or even induce failures. These include under or over-charging, incorrect ambient temperature, and battery conditions such as sulphation, corrosion or gassing.

Lithium-ion advantages

Lithium-ion batteries have a higher purchase price than VRLA products, costing up to 175 – 200% as much up front. However the total cost of ownership is less, especially as lithium-ion pricing has dropped significantly over the last two years. In any case, the purchase premium is offset because lithium-ion batteries last for 12 – 15 years compared with 7 – 8 years for VRLA. Further cost savings are possible, because they can operate at higher temperatures than VRLA products, and can be co-located in a room with UPSs and servers – saving on the expense of providing a separate battery room, and the cost of cooling it. As a related benefit, Lithium-ion batteries offer improved energy density, being up to 70% smaller and 60% lighter, significantly reducing storage space requirements.

Lithium-ion batteries are not maintenance-free, but maintenance costs are less than those for VRLA. End of life disposal costs are lower as well. Depending on chemistry, technology, temperature and depth of discharge, they also support up to ten times more discharge cycles, with a self-discharge rate – slow discharge while the battery is not in use – of about four times less than VRLA. Charging rate becomes four times faster or more.

When all the life time costs are factored in, lithium-ion’s initial price premium is eroded – and with prices continuing to drop, lithium-ion is starting to win the TCO race. And by reducing or even negating the price barrier, we’re left with a set of lithium-ion benefits as described above.

There are fears that lithium-ion represents a fire or worse. These have been strengthened by incidents such as the exploding Samsung G Note 7, hoverboards bursting into flames.

However, a review of whatÂ’s available will reveal that safer options exist, and are being used for data centre-type applications. UPS-specific batteries are being designed with lower power densities than those for phones, computers and hoverboars. While their power density has been reduced to meet safety requirements, it still exceeds that available from VRLA batteries. Some batteries have battery management systems certified under UL listings to meet the requirements of building inspectors and insurance companies.
Data centres and other installations needing power protection have traditionally favoured lead-acid batteries for UPS backup power, and the technology remains dominant today.

Other announcements from Kohler Uninterruptible Power

  • Understanding your UPS battery’s amp-hour rating

    If you’re specifying a UPS system, then it’s absolutely essential that you truly understand its battery autonomy; for how long will it support the load if the AC supplies fail?

    14 May 2018

  • Keeping UPS availability high

    When data centre operators invest in UPS systems, it’s for one purpose only; to maximise power availability for their facility’s ICT equipment.

    14 May 2018

  • Future trends for UPSs

    What does the future hold for UPS technologies and systems? We asked Alan Luscombe, Director at UPSL, for his views, as summarised below.

    02 Nov 2017

  • UPS, heal thyself

    UPSs exist solely to deliver clean, uninterrupted power to their critical load – but their ability to do so is entirely bounded by their resilience to failure of their own components or subsystems.

    31 Aug 2017

  • Maintaining UPS efficiency when the load size diminishes

    Modular UPS technology, as implemented in systems such as UPSL’s PowerWAVE 9500DPA, is now being exploited in a smart solution that maintains UPS efficiency even when the UPS load is severely reduced.

    30 Aug 2017

  • How UPS efficiency can contribute to data centre PUE

    Improving UPS efficiency can help to better data centre PUE performance. The article discusses the options for this available to UPS operators who invest in the right, transformerless technology UPSs.

    30 Aug 2017

  • The Internet of Things, data centres, and UPSs

    The Internet of Things (IoT) is gaining traction at an accelerating pace; Gartner has predicted 26 billion connected devices by 2020, while others are calling even higher numbers.

    30 Aug 2017

  • Director's Blog: So just what exactly is a UPS?

    This blog written by Alan Luscombe, UPS Ltd Director, explains what a UPS is, as well as putting the various risks averted by UPS systems into perspective.

    03 Aug 2015

  • Choosing a generator for data centre power protection

    UPS generators are no longer just a backup plan. Today, they are considered a vital component of a company’s power protection policy, as sizing UPS batteries for protracted power blackouts is simply uneconomic and impractical. In choosing a generator for a data centre or other critical IT load application, a number of factors must be considered. These include the generator’s key components, environmental issues and the qualifications of the suppliers as well as compatibility with the UPS to be supported. In this article, Alan Luscombe, director at Uninterruptible Power Supplies Ltd., a Kohler company, discusses how generators work with UPSs, and the factors you must consider when choosing a generator as part of your power protection policy.

    23 Jul 2015